Thrombotic Risk Reflex Panel

Last Literature Review: January 2025 Last Update:
Method

Electromagnetic Mechanical Clot Detection/Chromogenic Assay/Quantitative Enzymatic Assay/Semi-Quantitative Enzyme-Linked Immunosorbent Assay (ELISA)/Polymerase Chain Reaction (PCR)/Fluorescence Monitoring/Microlatex Particle-Mediated Immunoassay

This panel may be used to evaluate for inherited and acquired thrombophilias (eg, antiphospholipid syndrome, factor V Leiden ). This reflex panel provides a multistep combination of clot-based and other assays.

Test Description

Test Components and Reflex Patterns

When the Thrombotic Risk Reflex Panel is ordered, nine initial tests will always be ordered and performed by ARUP. These tests may also be ordered separately.

Tests Always Performed as Part of Thrombotic Risk Reflex Panel (3017156)
TestMethodStandalone Test Code
Antithrombin, Enzymatic (Activity)Chromogenic assay0030010
Protein S Free, AntigenMicrolatex particle-mediated immunoassay0098894
Protein C, FunctionalElectromagnetic mechanical clot detection0030113
Beta-2 Glycoprotein 1 Antibodies, IgG and IgMSemi-quantitative enzyme-linked immunosorbent assay0050321
Cardiolipin Antibodies, IgG and IgMSemi-quantitative enzyme-linked immunosorbent assay0099344
Prothrombin (F2) c.*97G>A (G20210A) Pathogenic VariantPolymerase chain reaction (PCR)/fluorescence monitoring0056060
Homocysteine, TotalQuantitative enzymatic assay0099869
APC Resistance Profile with Reflex to Factor V LeidenElectromagnetic mechanical clot detection/polymerase chain reaction (PCR)/fluorescence monitoring0030192
Lupus Anticoagulant Reflex PanelElectromagnetic mechanical clot detection/chromogenic assay3017009

Based on the results of the above assays, the following tests may be performed by reflex (additional charges apply):

Tests That May Be Performed by Reflex as Part of Thrombotic Risk Reflex Panel (3017156)
Reflex ReasonTest Added (Code)Method
Activated protein C (APC) resistance is low or invalid according to APC Resistance Profile with Reflex to Factor V Leiden (0030192)Factor V Leiden by PCR (0030194)Polymerase chain reaction (PCR)
Specific findings within the Lupus Anticoagulant Reflex PanelRefer to the Lupus Anticoagulant Reflex Panel Test Fact Sheet for information about the Lupus Anticoagulant Reflex Panel (3017009)

Test Interpretation

Sensitivity/Specificity

Varies

Results

Interpretive information, including the Reference Interval, is provided for each test component. Refer to the Example Reports on the ARUP Laboratory Test Directory for more information. For more information about anticoagulant neutralization in the lupus anticoagulant panel, refer to the Lupus Anticoagulant Reflex Panel Test Fact Sheet.

Limitations

  • Results should be interpreted within the context of a patient’s complete clinical picture.
  • The following factors may result in test interference or spurious results:
    • Acute phase reactions due to pregnancy, malignancy, inflammatory or infectious states, or trauma
    • Liver disease
    • Anticoagulant medications
    • Residual platelets (≥10,000 platelets/uL) in the plasma sample